Skillnader i vatten- och avloppshantering inom EU : En jämförelse mellan Slovakien och Sverige

The management of water resources and waste water varies between the countries of the EU. For many years, a large part of the water in Europe has been contaminated by, among other things, insufficiently treated waste water and emissions from agriculture. The EU Water Framework Directive 2000/60/EC and the Urban Waste Water Directive 91/271/EEC are intended to harmonize fresh-water management and waste water management within the whole EU, aiming at safeguarding drinking water of good quality and a high quality of all water within the EU today and in the future. There are however some problems concerning the waste-water directive. One problem is the huge investment needed in Slovakia to fulfil the demands of the waste-water directive for waste-water management in larger communities (with more than 2000 inhabitants).

Anaerob psykrofil behandling av hushållsavloppsvatten i UASB : Utvärdering av kapaciteten hos en två-stegs UASB-reaktor för behandling av hushållsavloppsvatten

Hammarby Sjöstad is a new district in southern Stockholm. A main objective with the Sjöstad project was to halve the environmental impact compared to other construction work. The environmental goals involve a halved water consumption rate, a local treatment of storm water and trials aiming to extract nutrients from the waste water. Sjöstadsverket is an experimental treatment plant used for testing new treatment processes for domestic waste water from Hammarby Sjöstad. The results are to be compared with the conventional process used at Henrikdals treatment plant today.

Kan perfluorerade ämnen i kläder bidra till förhöjda halter i reningsverk?

Perfluorinated substances (PF) are environmental pollutants that are used to coat fibres of so called ?all weather clothes? to make them water resistant. PF are effectively spread through water. Waste water treatment plants (WWTPs) are a pollutant source of these substances. PF are poisonous to different kinds of organisms, and supposedly also to human beings, if concentrations are sufficiently high.Perfluorinated substances have been investigated at three Waste water treatment plants in Stockholm during the 2000?s.

Bottensubstrat och dess inverkan på reducering av BOD5, COD och TKN i lakvatten genom konstruerade rotzonsanläggningar : En pilotstudie vid Univates, Lajeado ? RS Brasilien

Treatment wetlands been showed efficient for reducing pollutant in waste water. In Lajeado ? RS, Brazil the landfill has poor leachate water treatment. It is necessary to supplement the treatment plant because they need to reduce BOD, COD and nitrate of the water going to recipient. A subsurface flow wetland (SSF) can be a good choice.  In order to be able to design an efficient SSF it is important to understand how the grain sizes of a substrate affect the reducing of pollutants in waste water.

Rening av avloppsvatten med anaerob membranbioreaktor och omvänd osmos

This master's theses was carried out on assignment from Stockholm Vatten AB as a part of a project developing new Waste water treatment techniques. The goal of the theisis has been to evaluate an anaerobic membrane bioreactor for treatment of waste water from Hammarby Sjöstad. The bioreactor has not been heated and the main interest has been to study the gas production, power consumption and the reduction of organic matter and nutrients.The system has been completed with a reverse osmosis unit and a total of four batch runs have been made with good results. The use of reverse osmosis allows nutrient in the waste water to be reintroduced into circulation as the reverse osmosis concentrate can be used as crop nutrient.The membrane unit is of VSEP ("Vibratory Shear Enhanced Processing") type and an extensive membrane test has been conducted. This so called L-test helped determine the most suitable type of membrane for the system to allow a higher ±ux and thus lower power consumption.

Ombyggnation, från sågverkslokal till restaurang. antonio ziakoulis

Pharmaceuticals that are found in marine ecosystems are a threatening environmental concern, which is known to harm both animal and plant life. One of the reasons for this problem is that the Waste water treatment techniques are not optimized to clear waste water from its pharmaceuticals contain. In this master thesis four Swedish treatment wetlands were studied, and their ability to reduce numerous pharmaceuticals in waste water. The four treatment wetlands that were studied were those in Oxelösund, Trosa, Nynäshamn and Eskilstuna. Two ecotoxicological tests and chemical analysis were used.

Behandlingsvåtmarkers reningseffekt på aktiva läkemedelssubstanser under vinterförhållanden : En studie av fyra svenska våtmarker för avloppsrening

Pharmaceuticals that are found in marine ecosystems are a threatening environmental concern, which is known to harm both animal and plant life. One of the reasons for this problem is that the Waste water treatment techniques are not optimized to clear waste water from its pharmaceuticals contain. In this master thesis four Swedish treatment wetlands were studied, and their ability to reduce numerous pharmaceuticals in waste water. The four treatment wetlands that were studied were those in Oxelösund, Trosa, Nynäshamn and Eskilstuna. Two ecotoxicological tests and chemical analysis were used.

Rening av lakvatten vid deponin Degermyran i Skellefteå kommun : Utvärdering av nuvarande reningseffekt och simulering av mängden bildat lakvatten under 2000-talets klimatförändringar

At Degermyran landfill, situated in the municipal Skellefteå, a leachate treatment system was installed in 2005. One of the aims of this study was to investigate how well the treatment system works by using data from chemical measurements made on the leachate before and after treatment. Further this study had the purpose of investigating how the predicted climate changes of the 21st century will affect the amount of leachate generated at Degermyran by using a modified version of Thornthwaites water balance model. The treatment system has the ability of reducing manganese by 90 %, nitrogen by 73 % och TOC by 79 %. By the turn of this century the amount of precipitation that percolates the waste at Degermyran will be between 254 and 298 mm, depending on the amount of greenhouse gases that will be released in the future to come.

Reducering av produktionstryck i A-linan : Förflyttning av produkt

In the production of pulp, paper and cardboard, a large amount of water is used daily. The water has to be purified in the internal purifying plant before it reaches the receiving body of water. In the biological purifying stage at the Stora Enso Skoghall mill, an aerated basin is used where the microorganisms, using oxygen, oxidize the organic material to carbon dioxide. The air is pumped from the bottom of the basin and the oxygen can then be transported from the air bubbles to the water through diffusion. The problem with aeration of waste water from the forest industry is that wood residues, such as fatty acids, are making the transport of oxygen in water more difficult.

Identifiering av deponerat material i en deponi samt metodikförslag för upprättande av vattenbalans.

Högbytorp is Ragn-Sells? largest waste facility and it is located north of Stockholm. There is an old landfill still in use, but at the end of this year it will be closed. The waste deposited on the landfill can, through decomposition, give rise to a large amount of methane gas, which is an energy rich gas that can be used for heat and electricity production. To receive a relatively large amount of gas, the decomposition requires a high moisture content in the waste.

Analys av system för rening av avloppsvatten i en anaerob membranbioreaktor

The most common way to treat wastewater in Sweden today is by a combination of an activated sludge process and a chemical treatment. These processes are not very energy efficient and may not be the most environmentally friendly. That is why it is interesting to evaluate new alternative methods to see if they can be less harmful to the environment and help to a lower resource consumption. New techniques are tested in a pilot installation at Hammarby Sjöstad, Sjöstadsverket. To be able to evaluate these techniques in a wide perspective system analyses are conducted where different impacts can be considered, advantages and disadvantages in the systems.Five system structures for water treatment have been constructed in Matlab/Simulink in this study.

Käppalaverkets nuvarande och framtida rötningskapacitet : en studie i labskala

Käppala wastewater treatment plant situated on the island of Lidingö northeast of Stockholm is running a project during 2004 and 2005 with the purpose to map out the capacity of anaerobic digestion in the digesters that treat primary and excess sludge. The purpose of this thesis work, which is part of that project, was to characterize the present anaerobic digestion process and to investigate its capacity to treat other organic wastes such as restaurant waste and waste from water works. To decide the potential of both methane and biogas production from different substrates batch laboratory tests were carried out. To imitate the anaerobic digestion process at Käppala continuous tests with small scale reactors were carried out. These reactors were later fed with restaurant waste.The batch laboratory tests showed that primary sludge had a potential biogas and methane production of 0,62 and 0,35 Ndm3/g VS respectively after 40 days of digestion.

Beräkningsmodell för massbalanser för Slottshagens reningsverk

In the next few years the pollutants loading at the Slottshagen wastewater treatment plant in Norrköping is going to increase due to the reason that one of the Waste water treatment plant in the district will be shut down.A survey of how these different pollutants are divided in the treatment process is therefore necessary for mapping out both the loading and treatment efficiency.This can be achieved by studying mass balances.Mass balances were carried out for the water treatment process for the mechanical/chemical,biological and the chemical stage.The mass balance studies show that the treatment efficiency was very good. However in order for the mass balances to be quite consistent and to ensure complete coverage of results and conclusions i.e. more reliable results, sludge samples should be collected and taken at different times per day and the influent rate should be investigated.In this work mass balance has been set up in order to illustrate and identify the factors that should be considered and taken care of for further estimation using mass balances in the future. Furthermore this survey results in a calculating model for the mass balances at thisplant.This calculating model is used as a tool to facilitate future calculations for mass balances for the water treatment process at Slottshagens wastewater treatment plant.Moreover it provides a basis for carrying out further estimation of the treatment process in the near future.In this project the importance of some operating parameters was also taken in consideration.This calculating model can be modified so that calculations of such operating parameters i.e. sludge loading and sludge age can be easily performed.Such information can be used further to evaluate different operation alternative in order to ensure an optimal use of the treatment process with in the plant..

Avloppsvattenbehandling med membranbioreaktor : En jämförande systemanalys avseende exergi, miljöpåverkan samt återföring av närsalter

In the pilot plant at Hammarby Sjöstad, Sjöstadsverket, several new methods are tested in order to achieve a good use of resources. When a new technique is considered it is often the performance of the technique itself, under given conditions, that is evaluated. However, in order to evaluate the overall function the whole picture is needed. With a system analysis it becomes possible to make a comparison where all the positive aspects are put up against the negative ones, for the technique itself as well as its requirements. In this way the influence that minor components have on an entire system can be considered.This report presents a system analysis of an anaerobic membrane reactor (MBR) with a VSEP-membrane (Vibratory Shear Enhanced Process).

Fällning av kisel från avloppsvatten vid Hellisheidarvirkjun - experimentell studie

This report is about the experiments with mixing of the separated water and the vacuum pump seal water at Hellisheiði power plant. This is done to prevent silica scaling and clogging in pipes and reinjection wells as well as eliminating vacuum pump seal water from the plant. The experiments were done in four stages: the first stage comprised of tests with different flows of separated water at 70°C, the second stage was carried out by mixing the separated water at 70°C and the seal water with different amounts of the seal water, the third and the fourth stages were like the first and second but with the separated water at 120°C. The results show that this method is good if the mixture is around 50/50 separated water and seal water, to control the silica scaling in the separated water and to be able to reinject the seal water with the separated water. This does not eliminate the silica scaling in all of the separated water because the amount of separated water is much more than the amount of seal water that comes from the plant. .